{"id":157,"date":"2025-03-31T08:00:00","date_gmt":"2025-03-30T23:00:00","guid":{"rendered":"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/?post_type=trouble&#038;p=157"},"modified":"2025-03-31T10:47:50","modified_gmt":"2025-03-31T01:47:50","slug":"causes-and-countermeasures-for-fluid-leaks-and-hose-disconnections-precautions-on-hose-clamp-usage","status":"publish","type":"trouble","link":"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/trouble\/causes-and-countermeasures-for-fluid-leaks-and-hose-disconnections-precautions-on-hose-clamp-usage\/","title":{"rendered":"Causes and Countermeasures for Fluid Leaks and Hose Disconnections: Precautions on Hose Clamp Usage"},"content":{"rendered":"\n<div class=\"wp-block-group p-single-cm__block\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<div class=\"wp-block-group c-comment --intro\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<div class=\"wp-block-group c-comment__icon\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/themes\/toyox-hose-dr\/assets\/images\/single_cm_dr.webp\" alt=\"\"\/><figcaption class=\"wp-element-caption\">Hose Adviser PRO<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-group c-comment__content\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<p>When using hose clamps, keeping a few key points in mind can reduce the chances of leaks and disconnections. Hose Adviser PRO provides explanations on the causes of fluid leaks and hose disconnections, as well as on installing hose clamps in a manner that prevents problems from occurring.<\/p>\n<\/div><\/div>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-group c-list-point p-single-cm__block\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<p class=\"c-list-point__head\">Key points of this article<\/p>\n\n\n\n<ul class=\"wp-block-list c-list-point__list\">\n<li>Hoses should be tightened at a position above the indentation between the barbs in the center of the hose nipple.<\/li>\n\n\n\n<li>It may be necessary to install two hose clamps when the inner diameter is large or operating pressure is high.<\/li>\n\n\n\n<li>When using two hose clamps, they should be positioned in an offset pattern.<\/li>\n\n\n\n<li>They should not be overtightened or too loose, and a torque wrench should be used to maintain consistent tightening force.<\/li>\n<\/ul>\n<\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading c-h2-line--dot l-heading-level-2\">Properly Installing Hose Clamps to Prevent Leaks and Disconnections<\/h2>\n\n\n\n<p><\/p>\n\n\n\n<p>There are four main points to note for ensuring safe and secure installation of hose clamps in order to prevent leaks and disconnections.<br><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\"><strong>\u2460Hose clamp tightening position<\/strong><\/mark><\/p>\n\n\n\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\"><strong>\u2461Hose clamp quantity<\/strong><\/mark><\/p>\n\n\n\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\"><strong>\u2462Hose clamp orientation<\/strong><\/mark><\/p>\n\n\n\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\"><strong>\u2463Hose clamp tightening force<\/strong><\/mark><br><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p>Now, before explaining each key point, here\u2019s a question from Hose Adviser PRO.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-group p-single-cm__block\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<div class=\"wp-block-group c-comment --q\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<div class=\"wp-block-group c-comment__icon\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/themes\/toyox-hose-dr\/assets\/images\/single_cm_a.webp\" alt=\"\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-group c-comment__content\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<div class=\"wp-block-group c-comment-qa\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<p class=\"c-comment-qa__head\">What is the ideal position for installing the hose clamp when inserting the hose into the nipple and tightening it with a hose clamp?<br>Select from among A, B and C below.<\/p>\n<\/div><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"413\" src=\"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/f9d473a6a5a5c47a556605027b3ef9ad.jpg\" alt=\"\" class=\"wp-image-154\" srcset=\"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/f9d473a6a5a5c47a556605027b3ef9ad.jpg 1024w, https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/f9d473a6a5a5c47a556605027b3ef9ad-300x121.jpg 300w, https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/f9d473a6a5a5c47a556605027b3ef9ad-768x310.jpg 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-group c-comment --a\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<div class=\"wp-block-group c-comment__icon\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/themes\/toyox-hose-dr\/assets\/images\/single_cm_q.webp\" alt=\"\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-group c-comment__content\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<div class=\"wp-block-group c-comment-qa\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<h3 class=\"wp-block-heading c-comment-qa__head l-heading-level-3\">The correct answer is B. It should be installed in the center.<br>Let\u2019s see why B is the ideal position.<\/h3>\n<\/div><\/div>\n<\/div><\/div>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-group p-single-cm__block\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<h3 class=\"wp-block-heading c-h3-icon--plus l-heading-level-3\">1. Hose clamp tightening position<\/h3>\n\n\n\n<p><\/p>\n\n\n\n<p>The installation position of the hose clamp is important for preventing fluid leaks and hose disconnections.<\/p>\n\n\n\n<p>The hose clamp should be installed on the hose nipple (Fig. 1) so that it presses down on the indentation between the barbs (Fig. 2).<\/p>\n<\/div><\/div>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-group p-single-figure p-single-cm__block\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<p>                                                                     <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\"> (Fig.2)Install the clamp so that it presses down on the indentation between the barbs.<\/mark><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1030\" height=\"366\" src=\"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/cc1ac9b16906144259b5178a2e8b44f9.jpg\" alt=\"\" class=\"wp-image-158\" srcset=\"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/cc1ac9b16906144259b5178a2e8b44f9.jpg 1030w, https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/cc1ac9b16906144259b5178a2e8b44f9-300x107.jpg 300w, https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/cc1ac9b16906144259b5178a2e8b44f9-1024x364.jpg 1024w, https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/cc1ac9b16906144259b5178a2e8b44f9-768x273.jpg 768w\" sizes=\"auto, (max-width: 1030px) 100vw, 1030px\" \/><\/figure>\n\n\n\n<p><\/p>\n<\/div><\/div>\n\n\n\n<p>This will ensure the barbs bit into the hose, reducing the risk of the hose becoming disconnected or leaking fluid.<\/p>\n\n\n\n<p>Here\u2019s a video showing the correct installation position for the hose clamp.<\/p>\n\n\n\n<p>Click the link below to watch.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><a href=\"https:\/\/www.youtube.com\/watch?v=vNthGuQ7v0k\" target=\"_blank\" rel=\"noreferrer noopener\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\"><strong>\u3010the hose clamp\u3011Hose clamp tightening position(If the inner diameter of the hose is under 25 mm) <\/strong><\/mark><\/a><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-group p-single-cm__block\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<h3 class=\"wp-block-heading c-h3-icon--plus l-heading-level-3\">2. Hose clamp quantity<\/h3>\n\n\n\n<p><\/p>\n\n\n\n<p>We recommend installing two hose clamps for Toyox soft PVC hoses with an inner diameter of 25 mm or more, or when used under high operating pressure. Using two hose clamps reduces the risk of fluids leaking or the hose becoming disconnected.<\/p>\n<\/div><\/div>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-group p-single-figure p-single-cm__block\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">\u230025 or more<\/mark><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1371\" height=\"722\" src=\"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/0502224bbf57ddab5139cc69b009d80b.jpg\" alt=\"\" class=\"wp-image-159\" srcset=\"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/0502224bbf57ddab5139cc69b009d80b.jpg 1371w, https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/0502224bbf57ddab5139cc69b009d80b-300x158.jpg 300w, https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/0502224bbf57ddab5139cc69b009d80b-1024x539.jpg 1024w, https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/0502224bbf57ddab5139cc69b009d80b-768x404.jpg 768w\" sizes=\"auto, (max-width: 1371px) 100vw, 1371px\" \/><\/figure>\n<\/div><\/div>\n\n\n\n<p><\/p>\n\n\n\n<p>Here\u2019s a video showing how to install a hose clamp on a hose with an inner diameter of 25 mm or more.<\/p>\n\n\n\n<p>Click the link below to watch.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><a href=\"https:\/\/www.youtube.com\/watch?v=dj9_IG80KO4&amp;t=16s\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">\u3010the hose clamp\u3011Hose clamp tightening position(If the inner diameter of the hose is  25 or more) <\/mark><\/strong><\/a><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-group p-single-cm__block\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<h3 class=\"wp-block-heading c-h3-icon--plus l-heading-level-3\">3. Hose clamp orientation<\/h3>\n\n\n\n<p><br>If two hose clamps are installed with the housing in the same orientation, a gap may form as the hose clamp is fully tightened. (Fig. 3)<\/p>\n\n\n\n<p>We recommend tightening the hose clamps in an offset pattern to minimize gaps and prevent fluid leaks and hose disconnections.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-group p-single-figure p-single-cm__block\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">(Fig. 3)Housing orientation when tightening with two hose clamps<\/mark><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"264\" src=\"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/8bef01a52ef2ed7b6e02f83d3c8eb2c9.jpg\" alt=\"\" class=\"wp-image-160\" srcset=\"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/8bef01a52ef2ed7b6e02f83d3c8eb2c9.jpg 1024w, https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/8bef01a52ef2ed7b6e02f83d3c8eb2c9-300x77.jpg 300w, https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/8bef01a52ef2ed7b6e02f83d3c8eb2c9-768x198.jpg 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><\/p>\n<\/div><\/div>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-group p-single-cm__block\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<h3 class=\"wp-block-heading c-h3-icon--plus l-heading-level-3\">4. Hose clamp tightening force<\/h3>\n\n\n\n<p><\/p>\n\n\n\n<p>Overtightening hose clamps can damage the outside or inside of the hose, possibly resulting in fluid leaking. Likewise, undertightening can also lead to fluid leaking or the hose becoming disconnected. We recommend using a torque wrench to maintain a consistent tightening force.<\/p>\n\n\n\n<p>For those worried about torque control and retightening, we recommend using Toyox\u2019s TOYOCONNECTOR hose couplings, which eliminate the need for such maintenance.<\/p>\n\n\n\n<p>TOYOCONNECTOR hose couplings not only standardize work processes but also offer numerous benefits, such as reduced time spent on piping work and significant energy-saving effects. For more details, please click on the image below to view product information on a special website.<\/p>\n<\/div><\/div>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-group c-cta p-single-cm__block\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<div class=\"wp-block-group c-cta__inner\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<div class=\"wp-block-group c-cta__image\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"756\" src=\"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/campaign2406_feature02-1-1024x756.png\" alt=\"\" class=\"wp-image-161\" srcset=\"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/campaign2406_feature02-1-1024x756.png 1024w, https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/campaign2406_feature02-1-300x221.png 300w, https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/campaign2406_feature02-1-768x567.png 768w, https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-content\/uploads\/sites\/4\/2025\/01\/campaign2406_feature02-1.png 1374w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-group c-cta__content\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<h3 class=\"wp-block-heading c-cta__head l-heading-level-3\">[TOYOCONNECTOR: Zero leaks and disconnections]<\/h3>\n\n\n\n<p class=\"c-cta__text\">Offering many benefits other than leak and disconnection prevention!<\/p>\n\n\n\n<div class=\"wp-block-button c-cta__button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/english.toyox-hose.com\/member\/coupling\/search?method%5B%5D=2\" target=\"_blank\" rel=\"noreferrer noopener\">Click here for more details.<\/a><\/div>\n<\/div><\/div>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<p><\/p>\n\n\n\n<p>\u25a0 Click below to see video showing how TOYOCONNECTOR prevents leaks and disconnections<\/p>\n\n\n\n<p><a href=\"https:\/\/www.youtube.com\/watch?v=rXYK80-B840\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">\u3010Prevents leaks and disconnections\u3011Comparison of pressure resistance safety\u3010TOYOCONNECTOR\uff08TC3-B\uff09\u3011<\/mark><\/strong><\/a><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p>\u25a0 Click below to see a video showing how TOYOCONNECTOR compares with other couplings in terms of reduced work times and standardization<\/p>\n\n\n\n<p><a href=\"https:\/\/www.youtube.com\/watch?v=v946NKrs5A4\" data-type=\"link\" data-id=\"https:\/\/www.youtube.com\/watch?v=v946NKrs5A4\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">Comparison of installation workability\uff5cTOYOCONEECTOR VS Ordinary connector<\/mark><\/strong><\/a><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p>\u25a0 Click below to see how TOYOCONNECTOR compares with barb fittings in terms of energy savings, such as changes in energy consumption<\/p>\n\n\n\n<p><a href=\"https:\/\/www.youtube.com\/watch?v=XXsXwDj4-E8&amp;t=7s\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">[Energy Savings] TOYOCONNECTOR vs. Barb Fittings &#8211; Could the fittings change energy usage?<\/mark><\/strong><\/a><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p>That wraps up our explanation on installing hose clamps when piping hoses.<\/p>\n\n\n\n<p>For any other inquiries or consultations, please contact the TOYOX Customer Service Office.<\/p>\n\n\n\n<p><a href=\"https:\/\/english.toyox-hose.com\/member\/inquiry\" data-type=\"link\" data-id=\"https:\/\/english.toyox-hose.com\/member\/inquiry\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Click here to send an online inquiry<\/strong><\/a><\/p>\n\n\n\n<p><\/p>\n","protected":false},"featured_media":196,"template":"","format":"standard","meta":{"_acf_changed":false},"ct-trouble":[37],"class_list":["post-157","trouble","type-trouble","status-publish","format-standard","has-post-thumbnail","hentry","ct-trouble-fluid-leaks-hose-disconnections"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-json\/wp\/v2\/trouble\/157","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-json\/wp\/v2\/trouble"}],"about":[{"href":"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-json\/wp\/v2\/types\/trouble"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-json\/wp\/v2\/media\/196"}],"wp:attachment":[{"href":"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-json\/wp\/v2\/media?parent=157"}],"wp:term":[{"taxonomy":"ct-trouble","embeddable":true,"href":"https:\/\/www.hose-ad-pro.toyox.co.jp\/en\/wp-json\/wp\/v2\/ct-trouble?post=157"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}